- Governer malfunctioning
- Governer oil dirty
- Droop setting not proper
- Sticky linkages
- Water in fuel and air lock in fuel line
- Fuel oil filter chocked and fuel quality poor
- Viscosity not maintained.
- Scavenge air pressure low- fouling of T/C , suction filter dirty , air cooler chocked
- Improper tappet clearance
- Overdue for decarb
- Slippage of cam and cam shaft- thus alteration in fuel pump timing, inlet and exhaust valve timing
- Fuel pump overhauling due
Interlocks are provided so that the engine can be started or reversed only when certain conditions have been fulfilled. When there is a remote control of engines, it is essential to have interlocks. This reduces the possibility of engine damage and any hazards to the operating personnel. Turning gear Interlock . This device prevents the engine from being started if the Turning gear is engaged. Running Direction Interlock . This prevents the fuel from being supplied if the running direction of the engine does not match the Telegraph. Starting Air Distributor in end position . This prevents starting from taking place if the shifting of the Distributor has not been completed. Main Lube. oil pressure, Piston cooling pressure, Jacket water pressure, and important parameters must be above the required minimum. Auxiliary Blower Interlock . The Auxiliary Blower is provided in case of Constant pressure turbo charging. Air Spring pressure Interlock . In case of the present generation...