a. Check that the generator lube oil systems valves are correctly positioned and that the
sump filling valve is holding
b. Ask the personnel for if they have carried out any transfers just before, related to the
sump oil of the generator
c. Check the purifier for correct operation and that no water is being discharged with the
purified oil
d. Change over the generator concerned, isolate it and check the sump for any
contamination like water. Basing on the findings further inspections can be carried
out, like checking the cylinder liner jacket cooling water sealing O-ring etc.,
sump filling valve is holding
b. Ask the personnel for if they have carried out any transfers just before, related to the
sump oil of the generator
c. Check the purifier for correct operation and that no water is being discharged with the
purified oil
d. Change over the generator concerned, isolate it and check the sump for any
contamination like water. Basing on the findings further inspections can be carried
out, like checking the cylinder liner jacket cooling water sealing O-ring etc.,